ThinkServerTD340UserGuideandHardwareMaintenanceManualMachineTypes:70B4,70B5,70B6,and70B7
Statement11CAUTION:Thefollowinglabelindicatesapotentialheathazard.Statement12DANGEROverloadingabranchcircuitisapotentialfirehazardandashockhazardunderc
3.Removethefrontbezelbyreleasingthethreeplastictabsontheleftsideandpivotingthefrontbezeloutward.Figure36.Removingthefrontbezel88ThinkServerTD340UserGu
4.Toreinstallthefrontbezel,aligntheotherthreeplastictabsontherightsideofthefrontbezelwiththecorrespondingholesinthechassis,thenpivotthefrontbezelinwar
a.Pressthereleasetab1inthedirectionasshown,andthencarefullyliftthePCIcardbracketassemblyslightlyupwarduntilthetwomountingstuds2onthechassisareinthecen
5.ReinstallthePCIcardbracketassemblybydoingthefollowing:a.Installthesmalllow-profilePCIcardbracketintothemainPCIcardbracket.•TosecurethePCIcardseatedin
b.PlacethePCIcardbracketassemblyintothechassissothatthetwomountingstuds2onthebottomofthechassisareinsertedintothecorrespondingholesinthePCIcardbracket
InstallingorremovingamemorymoduleThistopicprovidesinstructionsonhowtoinstallorremoveamemorymodule.Note:ThememorymodulesaresensitivetoESD.Ensurethatyou
Thefollowingillustrationshowsthelocationsofallmemoryslotsonasystemboardthathastwomicroprocessors(alsoknownasCPUs)installed.Figure43.Memoryslotsonthesy
Table5.MemorymoduleinstallationrulesforserverswithonemicroprocessorCPU1DIMMA1A2B1B2C1C2OneDIMMXTwoDIMMsXXThreeDIMMsXXXFourDIMMsXXXXSixDIMMsXXXXXXThefo
MemorymoduleinstallationorderinindependentmodeThissectionexplainsthememorymoduleinstallationorderinindependentmode.Inthismode,theRASfeaturesarenotavai
MemorymoduleinstallationorderinsparingmodeThissectionexplainsthememorymoduleinstallationorderinsparingmode.Thesparingmodeprovidesmemoryredundancy.Inth
Statement16CAUTION:Toreducetheriskofelectricshockorenergyhazards:•Thisequipmentmustbeinstalledbytrainedservicepersonnelinarestricted-accesslocation,as
Thefollowingtableexplainsthememorymoduleinstallationorderforserversthathavetwomicroprocessors(CPU1andCPU2)installed.Table14.Memorymoduleinstallationor
7.Touchthestatic-protectivepackagethatcontainsthenewmemorymoduletoanyunpaintedsurfaceontheoutsideoftheserver.Then,takethenewmemorymoduleoutofthepackag
5.Removeanypartsordisconnectanycablesthatmightpreventyouraccesstothememoryslots.6.Locatethememorymodulethatyouwanttoremoveandopentheretainingclipsonbo
•Ifyourserverhasonemicroprocessorinstalled,theEthernetcardcanbeinstalledintothePCI-Eslot2orPCI-Eslot5.Ifyourserverhastwomicroprocessorsinstalled,theEt
9.PositionthenewEthernetcardoverthePCIExpresscardslotforwhichyouhaveremovedtheslotbracket,andthencarefullypresstheEthernetcardstraightdownuntilitissec
Themostup-to-datedevicedriversforvariousservermodelsarealwaysavailablefordownloadontheLenovoSupportWebsiteat:http://www.lenovo.com/driversRemovingtheE
7.RemovethescrewthatsecurestheEthernetcard.Then,grasptheEthernetcardbyitsedgesandcarefullypullitoutofthePCIExpresscardslot.Note:TheEthernetcardfitstigh
InstallingtheRAIDcardAttention:Donotopenyourserverorattemptanyrepairbeforereadingandunderstanding“Safetyinformation”onpageiiiand“Guidelines”onpage83.T
versionoftheFirmwareUpdaterprogramdoesnotcontainthelatestversionofthedriveryouneed,downloadthatdriverseparatelyfromtheWebpageandinstallitindividuallyt
•Toworkwithanotherpieceofhardware,gototheappropriatesection.•Tocompletetheremovalprocedure,goto“Completingthepartsreplacement”onpage205.Then,youneedto
Statement20CAUTION:Alithiumionbatteryisprovided.Toavoidpossibleexplosion,donotburnthebattery.ReplacethebatteryonlywiththeLenovo-approvedpart.Recycleor
3.DisconnectthecablefromtheThinkServerRAIDSuperCapacitorModuleandthenremovethescrewthatsecurestheThinkServerRAIDSuperCapacitorModulebracket.Then,holdt
6.NotetheorientationofthenewThinkServerRAIDSuperCapacitorModule.Then,gentlypressthetab1onthebracketandinstallthenewThinkServerRAIDSuperCapacitorModule
8.ConnectthenewThinkServerRAIDSuperCapacitorModuletotheextendedcablefromtheThinkServerRAID710Adapter.Figure56.ConnectingthenewThinkServerRAIDSuperCapa
Toinstallthesoftwarekey,locatethesoftwarekeyconnectorontheThinkServerRAID710Adapterandtheninsertthesoftwarekeyintothesoftwarekeyconnector.Figure57.Ins
ToinstalltheCacheCadekey,locatetheCacheCadekeyconnectorontheThinkServerRAID710AdapterandtheninserttheCacheCadekeyintotheCacheCadekeyconnector.Figure58
Beforeyoubegin,printalltherelatedinstructionsorensurethatyoucanviewthePDFversiononanothercomputerforreference.Note:Useanydocumentationthatcomeswiththe
RemovingtheTR500KeyAttention:Donotopenyourserverorattemptanyrepairbeforereadingandunderstanding“Safetyinformation”onpageiiiand“Guidelines”onpage83.Thi
7.IfyouareinstructedtoreturntheoldTR500Key,followallpackaginginstructionsanduseanypackagingmaterialsthataresuppliedtoyouforshipping.Whattodonext:•Towo
Note:CarefullyhandletheThinkServerRAID700Adapterbyitsedgesandplaceitonaflat,clean,andstatic-protectivesurfaceafteryouremoveit.6.Touchthestatic-protecti
Beforeyoubegin,printalltherelatedinstructionsorensurethatyoucanviewthePDFversiononanothercomputerforreference.Notes:•IfyouremovetheTR700Battery,youwil
Chapter1.GeneralinformationThischapterprovidessomegeneralinformationaboutyourproduct.Thischaptercontainsthefollowingitems:•“Introduction”onpage1•“Serv
InstallingorremovingtheThinkServerRAID100orRAID300upgradekeyforAdvancedRAIDYourserversupportsboththeThinkServerRAID100upgradekeyforAdvancedRAID(herein
6.InsertonesideoftheTR100orTR300KeyunderoneoftheretainingclipsontheiButtonsocket.Then,carefullypresstheothersideoftheTR100orTR300Keystraightdownuntilt
Notes:•IfyouremovetheTR100orTR300Key,theonboardSATAorSASsoftwareRAID5willbedisabledcorrespondingly.•UseanydocumentationthatcomeswiththeTR100orTR300Key
Whattodonext:•Toworkwithanotherpieceofhardware,gototheappropriatesection.•Tocompletetheremovalprocedure,goto“Completingthepartsreplacement”onpage205.A
5.LocatetheTMMPremiumconnectoronthesystemboard,andtheninserttheTMMPremiumintotheTMMPremiumconnector.Note:EnsurethattheTMMPremiumissecurelyseatedonthes
Notes:•IfyouremovetheTMMPremium,theiKVMfunctionforserverremotemanagementwillbeunavailable.•UseanydocumentationthatcomeswiththeTMMPremiumandfollowthose
InstallingorremovingtheThinkServerTrustedPlatformModuleThistopicprovidesinstructionsonhowtoinstallorremovetheThinkServerTrustedPlatformModule(hereinaf
5.LocatetheTPMconnectoronthesystemboard,andtheninserttheTPMintotheTPMconnector.Figure67.InstallingtheTPMWhattodonext:•Toworkwithanotherpieceofhardware
•Dependingonthemodel,yourservermightlookslightlydifferentfromtheillustrationinthistopic.ToremovetheTPM,dothefollowing:1.Removeallmediafromthedrivesand
InstallingorremovingtheintelligentdiagnosticsmoduleThistopicprovidesinstructionsonhowtoinstallorremovetheintelligentdiagnosticsmodule(hereinafterrefer
Recordinformationaboutyourserverinthefollowingtable.Youwillneedtheinformationifyoueverneedtohaveyourserverserviced.Forwheretofindtheproductinformationl
6.RoutethesignalcableoftheIDMthroughthecorrespondingholeinthechassisandpositiontheIDMonthechassissothatthescrewholeintheIDMisalignedwiththecorrespondi
8.ConnecttheotherendofthesignalcabletotheIDMconnectoronthesystemboard.See“Systemboardcomponents”onpage48.Then,properlyroutethesignalcableoftheIDM.Youm
1.Removeallmediafromthedrivesandturnoffallattacheddevicesandtheserver.Then,disconnectallpowercordsfromelectricaloutletsanddisconnectallcablesthatareco
InstallingorreplacinganopticaldriveAttention:Donotopenyourserverorattemptanyrepairbeforereadingandunderstanding“Safetyinformation”onpageiiiand“Guideli
Notes:•Dependingonthemodel,yourservermightlookslightlydifferentfromtheillustrationsinthistopic.•Useanydocumentationthatcomeswiththeopticaldriveandfoll
•Ifyouarereplacinganopticaldrive,disconnectthesignalcableandthepowercablefromtherearoftheopticaldrive.Pressthereleasebutton1inthedirectionasshownandpu
6.Slidethenewopticaldriveintothedrivebayfromthefrontuntilitsnapsintoposition.Note:Youdonotneedtoremovethefrontbezelwhenreplacinganopticaldrive.However
•Ifyouareinstallinganopticaldrive,savetheremovedEMI-protectiveshieldfromthechassisandplasticshieldfromthefrontbezelintheeventthatyoulaterremovethedriv
•Dependingonthemodel,yourservermightlookslightlydifferentfromtheillustrationsinthistopic.•Useanydocumentationthatcomeswiththehot-swapharddiskdriveandf
3.Pressthereleasebutton1toopenthehandleofthehot-swapharddiskdriveorthedummytray.Figure77.Openingthehandleofthehot-swapharddiskdriveorthedummytrayChapt
Note:LenovomaintainspagesontheWorldWideWebwhereyoucangetthelatesttechnicalinformationanddownloaddocumentationordevicedriversandupdates.Someinformation
4.Pullthehandleandcarefullyslidethehot-swapharddiskdriveorthedummytrayoutofthefrontofthechassis.Figure78.Removingthehot-swapharddiskdriveorthedummytra
6.Slidethenewhot-swapharddiskdriveintothedrivebayfromthefrontuntilitsnapsintoposition,andthencompletelyclosethehandle.Figure79.Installingthehot-swapha
ForalistofThinkServerharddiskdriveoptions,goto:http://www.lenovo.com/thinkserverTheEMIintegrityandcoolingoftheserverareprotectedbyhavingalldrivebaysco
2.Usethefrontdoorkeytounlockthefrontdoor,andthenusethefrontdoorhandle1topivotthefrontdoortotheopenposition.Figure80.Openingthefrontdooroftheserver3.Re
4.Thenon-hot-swapharddiskdrivesareinstalledinthelowerhard-disk-drivecageandareprotectedbyanEMI-protectivepanel.Pressthesmalltab1ontheEMI-protectivepan
8.Installthenewnon-hot-swapharddiskdriveintoabluebracketbyflexingthesidesofthebracketandaligningpin1,pin2,pin4,andpin5onthebracketwiththecorrespondingh
13.AlignthetopedgeoftheEMI-protectivepanelwiththetopsideofthehard-disk-drivecage,andthenpivottheEMI-protectivepaneldownuntilitsnapsintoposition.Figure
Beforeyoubegin,printalltherelatedinstructionsorensurethatyoucanviewthePDFversiononanothercomputerforreference.Notes:•Dependingonthemodel,yourservermig
4.Thenon-hot-swapharddiskdrivesareinstalledinthelowerhard-disk-drivecageandareprotectedbyanEMI-protectivepanel.Pressthesmalltab1ontheEMI-protectivepan
7.Inserttwofingersintotheholesinthetwotabsonthefrontofthebluebracket.Then,pressthetabstowardseachotherandcarefullyslidethenon-hot-swapharddiskdriveouto
4ThinkServerTD340UserGuideandHardwareMaintenanceManual
10.AlignthetopedgeoftheEMI-protectivepanelwiththetopsideofthehard-disk-drivecage,andthenpivottheEMI-protectivepaneldownuntilitsnapsintoposition.Figure
TheEMIintegrityandcoolingoftheserverareprotectedbyhavingalldrivebayscoveredoroccupied.Thenumberoftheinstalledharddiskdrivesorsolid-statedrivesinyourse
2.Pressthereleasebutton1toopenthehandleofthedummytray.Figure89.Openingthehandleofthedummytray150ThinkServerTD340UserGuideandHardwareMaintenanceManual
3.Pullthehandleandcarefullyslidethedummytrayoutofthefrontofthechassis.Figure90.Removingthedummytray4.Touchthestatic-protectivepackagethatcontainsthe2.
5.Positionthe2.5-inchsolid-statedriveintothe3.5-inchto2.5-inchdriveadapterasshowninthefollowingillustration.Figure91.Positioningthe2.5-inchsolid-state
7.Positionthedriveadapterandthesolid-statedriveintothe3.5-inchdrivebracket.Alignthescrewholesinthedriveadapterandthesolid-statedrivewiththecorrespondi
harddiskdrivestatusLEDs”onpage33.Ifthesolid-statedriveisfaulty,reinstallorreplaceituntilitisoperatingcorrectly.10.Closeandlockthefrontdoor.11.Savether
2.Pressthereleasebutton1toopenthehandleofthe3.5-inchdrivebracket.Figure95.Openingthehandleofthe3.5-inchdrivebracketChapter6.Installing,removing,orrepl
3.Pullthehandleandcarefullyslidethebracketwiththesolid-statedriveoutofthefrontofthechassis.Figure96.Removingthebracketwiththesolid-statedrive4.Removet
5.Removethetwoscrewsthatsecurethesolid-statedrive.Figure98.Removingthescrewsthatsecurethesolid-statedrive6.Liftthesolid-statedriveuptoremoveitfromthed
Chapter2.ServersetuproadmapThischapterprovidesageneralroadmaptoguideyouthroughsettingupyourserver.Theserversetupprocedurevariesdependingontheconfigurat
•“Connectinganexternaltapedrive”onpage162ForalistofThinkServertapedriveoptions,goto:http://www.lenovo.com/thinkserverInstallingorreplacinganinternalRD
•IfyouareinstallinganRDXdrive,removethefrontbezel.See“Removingandreinstallingthefrontbezel”onpage87.Then,removetheplasticshieldforthebayfromthefrontpa
•IfyouarereplacinganRDXdrive,disconnectthesignalcableandthepowercablefromtherearoftheRDXdrive.Pressthereleasebutton1inthedirectionasshownandpushtheRDX
6.SlidethenewRDXdriveintotheopticaldrivebayfromthefrontuntilitsnapsintoposition.Note:YoudonotneedtoremovethefrontbezelwhenreplacinganRDXdrive.However,
•IfyouarereplacinganRDXdriveandareinstructedtoreturntheoldRDXdrive,followallpackaginginstructionsanduseanypackagingmaterialsthataresuppliedtoyouforshi
Dependingonthemodel,yourservermightcomewithoneortwomicroprocessors.Forservermodelswithonemicroprocessor,themicroprocessorisinstalledinthemicroprocesso
5.Pressdownthesmallhandleonthemicroprocessorsocket,andthenpullthehandlealittlebitoutwardtoreleaseitfromthesecuredposition.Then,gentlypressthemicroproc
8.Removetheprotectivecoverthatprotectsthegoldcontactsonthebottomofthenewmicroprocessor.Donottouchthepinsonthemicroprocessorsocketandthegoldcontactsont
10.Gentlyclosethemicroprocessorretainer,pressdownthesmallhandle,andthenpushthehandleinwardtolocktheretainerintopositionandsecurethenewmicroprocessorin
Beforeyoubegin,printalltherelatedinstructionsorensurethatyoucanviewthePDFversiononanothercomputerforreference.Notes:•Ensurethatthenewmicroprocessorist
6ThinkServerTD340UserGuideandHardwareMaintenanceManual
6.Touchonlytheedgesofthemicroprocessorandcarefullyliftitstraightupandoutofthemicroprocessorsocket.Placetheoldmicroprocessoronastatic-protectivesurface
9.Notetheorientationofthenewmicroprocessor.Holdthenewmicroprocessorbyitsedgesandalignthenotches1onitwiththetabs2inthemicroprocessorsocket.Then,careful
10.Gentlyclosethemicroprocessorretainer,pressdownthesmallhandle,andthenpushthehandleinwardtolocktheretainerintopositionandsecurethenewmicroprocessorin
Someservermodelscomewithonlyonepowersupply.Youcanpurchaseahot-swapredundantpowersupplyoptionfromLenovo.CAUTION:Hazardousmovingparts.Keepfingersandother
•Ifyouareinstallingahot-swapredundantpowersupply,locatethebayforthepowersupplyintherearofyourserver.Insertafingerintotheholeinthemetalshieldthatprotect
2.Ifyouarereplacingahot-swapredundantpowersupply,pressthereleasetab1inthedirectionasshownandcarefullypullthehandle2atthesametimetoslidethefailinghot-s
5.Connectthepowercordtothepowercordconnectoronthenewhot-swapredundantpowersupply.Then,checkthestatusLEDnearthepowercordconnector.WhentheLEDislitingree
10.IfyouareinstructedtoreturntheoldPCIExpresssolid-statedrive,followallpackaginginstructionsanduseanypackagingmaterialsthataresuppliedtoyouforshipping
3.Laytheserveronitssideforeasieroperation.4.Removethefrontsystemfans.See“Replacingthefrontsystemfan1”onpage188.5.Recordthecableroutingandconnection.Th
9.InstallthenewpowersupplyassemblyintothechassissothatthefourscrewholesinthenewpowersupplyassemblyarealignedwiththecorrespondingholesmarkedwithAinther
Chapter3.ProductoverviewThischapterprovidesinformationabouttheserverpackage,features,specifications,softwareprograms,andcomponentlocations.Thischapterc
Thistopicprovidesinstructionsonhowtoreplacethehot-swaphard-disk-drivebackplane.Thistopicappliesonlytoservermodelsthathavehot-swapharddiskdrivesinstall
8.Liftthereleaselatch1andslidethehard-disk-drivecageoutofthefrontofthechassis.Note:Thefollowingillustrationshowsthe3.5-inchhard-disk-drivecage.Forthe2
•Forthe2.5-inchhot-swaphard-disk-drivebackplane,removethesixscrewsorthreescrewsthatsecurethebackplanedependingonthetypeofthebackplane.Then,removetheba
•Forthe2.5-inchhot-swaphard-disk-drivecage,installthesixscrewstosecurethebackplaneonthecage.Figure124.Installingthe2.5-inchhot-swaphard-disk-driveback
12.Slidethehard-disk-drivecageintothechassisfromthefrontuntilitsnapsintoposition.Note:Thefollowingillustrationshowsthe3.5-inchhard-disk-drivecage.Fort
CAUTION:Hazardousmovingparts.Keepfingersandotherbodypartsaway.CAUTION:Neverremovethecoveronapowersupplyoranypartthathasthefollowinglabelattached.Hazard
8.Removethetwoscrewsattherearofthechassisandthetwoscrewsonthemetalclipatthefrontofthepowerdistributionboardandcageassembly.Then,pushthepowerdistributi
10.Installthenewpowerdistributionboardandcageassemblyintothechassissothatthetwoscrewholesintherearofthenewpowerdistributionboardandcageassemblyarealig
Beforeyoubegin,printalltherelatedinstructionsorensurethatyoucanviewthePDFversiononanothercomputerforreference.Notes:•Dependingonthemodel,yourservermig
8.Removethescrew1onthechassisthatsecuresthefrontpanelboardassembly.Then,carefullyremovethefrontpanelboardassemblyfromthechassisandpullthesignalcableso
Note:Beforeusingtheinformationandtheproductitsupports,besuretoreadandunderstandthefollowing:•TheReadMeFirstthatcomeswithyourproduct•“Safetyinformation
refertothePersonalSystemsReferencedocumentforThinkServerproductsat:http://www.lenovo.com/psref/MicroprocessorOneortwoIntel®Xeon®microprocessors(intern
11.Routethesignalcablesofthenewfrontpanelboardassemblythroughthecorrespondingholeinthechassisandpositionthenewfrontpanelboardassemblyonthechassissotha
CAUTION:Hazardousmovingparts.Keepfingersandotherbodypartsaway.Beforeyoubegin,printalltherelatedinstructionsorensurethatyoucanviewthePDFversiononanother
6.Touchthestatic-protectivepackagethatcontainsthenewfrontsystemfan1toanyunpaintedsurfaceontheoutsideoftheserver.Then,removethenewfrontsystemfan1fromth
CAUTION:Hazardousmovingparts.Keepfingersandotherbodypartsaway.Beforeyoubegin,printalltherelatedinstructionsorensurethatyoucanviewthePDFversiononanother
5.Therearsystemfanisattachedtothechassisbyfourrubbermounts.Removetherearsystemfanbycuttingtherubbermountsandpullingtherearsystemfanoutofthechassis.Fig
7.Positionthenewrearsystemfan,whichhasfournewrubbermountsattached,onthechassissothatthefournewrubbermountsarealignedwiththecorrespondingholesinthechas
CAUTION:Hazardousmovingparts.Keepfingersandotherbodypartsaway.CAUTION:Theheatsinkandfanassemblymightbeveryhot.Turnofftheserverandwaitthreetofiveminutest
6.Removethefourscrewsthatsecuretheheatsinkandfanassembly1tothesystemboard.Itisrecommendedthatyoucarefullyremovethefourscrewsfromthesystemboardusingthe
10.Installthefourscrewstosecurethenewheatsinkandfanassembly1onthesystemboard.Itisrecommendedthatyoucarefullyinstallthefourscrewsusingthefollowingmetho
lastsforever.Ifthesystemboardbatteryfails,thedate,time,andconfigurationinformation,includingpasswords,arelostandanerrormessageisdisplayedwhenyouturnont
Note:Theterm“2.5-inchhot-swapharddiskdrives”or“2.5-inchharddiskdrives”hereinafterreferstoallthesupportedtypesof2.5-inchharddiskdrives,includingthesoli
6.Removetheoldsystemboardbattery.Figure137.Removingthesystemboardbattery7.Installanewsystemboardbattery.Figure138.Installingthesystemboardbattery8.Rei
CAUTION:Theheatsinksandmicroprocessorsmightbeveryhot.Turnofftheserverandwaitthreetofiveminutestolettheservercoolbeforeremovingtheservercover.Beforeyoub
13.Disconnectallcablesfromthesystemboard.Then,removethetenscrewsthatsecurethesystemboardfollowingtherecommendednumericalsequenceasshown.Figure139.Remo
14.Gentlylifteachedgeofthesystemboardalittlebitupwardsothatthesystemboardisreleasedfromthemountingstudsonthechassis.Then,movethesystemboardtothefronto
16.Installthenewsystemboardintothechassisasshown.Ensurethattherearconnectorsonthenewsystemboardareinsertedintothecorrespondingholesintherearpanelandth
17.Installthetenscrewsfollowingtherecommendednumericalsequenceasshowntosecurethenewsystemboardonthechassis.Figure142.Installingthescrewstosecurethesys
b.Positionthemicroprocessorsocketcoverabovethemicroprocessorsocketsothatthesmalltriangle1onthesocketcoverfacesthesmalltriangle2onthemicroprocessorreta
Whattodonext:•Toworkwithanotherpieceofhardware,gototheappropriatesection.•Tocompletethereplacement,goto“Completingthepartsreplacement”onpage205.•After
4.Positiontheservercoveronthechassissothattherailonthebottomoftheservercoverengagesthebottomrailonthechassis.Then,alignthefourtabs1ontheservercoverwit
6.Tightenthethumbscrewontheservercovertosecuretheservercoverinplace.Note:Forsafetyconsideration,ensurethatyouuseatool,forexampleascrewdriver,totighten
Reliability,availability,andserviceabilityReliability,availability,andserviceability(hereinafterreferredtoasRAS)arethreeimportantserverdesignfeatures.
208ThinkServerTD340UserGuideandHardwareMaintenanceManual
Chapter7.TroubleshootinganddiagnosticsThischapterprovidesinformationaboutbasictroubleshootinganddiagnosticmethodstohelpyousolveproblemsthatmightoccuri
1.Gotohttp://www.lenovo.com/driversandfollowtheinstructionsontheWebpagetolocateadiagnosticprogram.2.Downloadandunzipthediagnosticprogrampackagetogetth
SymptomActionthroughtheprogrammaininterface.See“StartingtheThinkServerEasyStartupprogram”onpage69.2.Verifyiftheopticaldriveorthedischasproblems.See“Op
SymptomAction8.Replacethesignalcablefortheopticaldrive.9.Replacetheopticaldrive.HarddiskdriveproblemsFollowthesuggestedactionsforthecorrespondingsympt
SymptomAction8.Reconnectthebackplanesignalcableandrepeatstep1throughstep4.9.Ifyoususpectaproblemwiththebackplanesignalcableorthebackplane:a.Replacethe
Keyboard,mouse,orUSBdeviceproblemsFollowthesuggestedactionsforthecorrespondingsymptomintheorderinwhichtheyarelisteduntiltheproblemissolved.Ifnoneofthe
Chapter8.Gettinginformation,help,andserviceThischaptercontainsinformationabouthelp,service,andtechnicalassistanceforproductsmanufacturedbyLenovoandwhe
•Driversandsoftware•Diagnosticsolutions•Productandservicewarranty•Productandpartsdetails•Userguidesandmanuals•Knowledgebaseandfrequentlyaskedquestions
Thewarrantydoesnotcoverthefollowing:•ReplacementoruseofpartsnotmanufacturedfororbyLenovoornon-warrantedLenovoparts•Identificationofsoftwareproblemsourc
–PrebootExecutionEnvironment(PXE)TheIntelPXEtechnologyenablesyoutobootyourcomputers,loadanoperatingsystem,ordeployexecutableimagesfromaremoteserverbyu
218ThinkServerTD340UserGuideandHardwareMaintenanceManual
AppendixA.NoticesLenovomaynotoffertheproducts,services,orfeaturesdiscussedinthisdocumentinallcountries.ConsultyourlocalLenovorepresentativeforinformat
TrademarksLenovo,theLenovologo,andThinkServeraretrademarksofLenovointheUnitedStates,othercountries,orboth.Intel,IntelCore,andIntelXeonaretrademarksofI
orreplacementofserversorpartsonimplementationofappropriateremedialmeasurestomitigatesuchenvironmentalcontamination.Implementationofsuchremedialmeasure
BatteryrecyclinginformationfortheEuropeanUnionNotice:ThismarkappliesonlytocountrieswithintheEuropeanUnion(EU).Batteriesorpackagingforbatteriesarelabel
ImportantWEEEinformationTheWEEEmarkingonLenovoproductsappliestocountrieswithWEEEande-wasteregulations(forexample,EuropeanDirective2002/96/EC,IndiaE-Wa
ElectronicemissionnoticesThefollowinginformationreferstotheLenovoThinkServermachinetypes70B4,70B5,70B6,and70B7.FederalCommunicationsCommission(FCC)Sta
Warning:ThisisaClassAproduct.Inadomesticenvironmentthisproductmaycauseradiointerferenceinwhichcasetheusermayberequiredtotakeadequatemeasures.GermanCla
ENERGYSTARmodelinformationENERGYSTAR®isajointprogramoftheU.S.EnvironmentalProtectionAgencyandtheU.S.DepartmentofEnergyaimedatsavingmoneyandprotectingt
Index2.5-inchhot-swaphard-disk-drivebackplanelocations423.5-inchhot-swaphard-disk-drivebackplanelocations40AaboutRAID72AdvancedmenuSetupUtilityprogram
SpecificationsThistopicliststhephysicalspecificationsforyourserver.DimensionsWidth:195mm(7.68inches)Height:430mm(16.93inches)withoutfootstands;445mm(17.
frontsystemfanreplacing188frontviewoftheserverlocations15Ggaseouscontamination220Germanglossstatement223gettinghelp215gettinginformation215gettingserv
locations13LSISoftwareRAIDConfigurationUtilityprograminterface74starting74Mmachinetypeandmodellabellocations13MainmenuSetupUtilityprogram62MegaRAIDStor
TR700Battery116replaceinternalRDXdrive158replacingfrontpanelboardassembly185frontsystemfan188hardware83heatsinkandfanassembly1193hot-swapharddiskdrive
features69starting69using69Windowsoperatingsystem71ThinkServerEasyUpdateFirmwareUpdatersoftware12ThinkServerManagementModulestatusLED57ThinkServerRAID
232ThinkServerTD340UserGuideandHardwareMaintenanceManual
BIOSandTMMupdateutilitiesTheBIOSandTMM(alsoknownasBMC)firmwarekeepsupdatingaftertheshipmentoftheserver.LenovomaintainspagesontheSupportWebsiteandprovid
Thefollowingillustrationisasampleofthemachinetype,model,andserialnumberlabelsontheserver.Note:Dependingonthemodeltype,yourservermightlookslightlydiffe
FrontviewoftheserverThistopicprovidesinformationtohelpyoulocatethepartsonthefrontoftheserver.Thefollowingillustrationshowsthefrontviewoftheserver.CPUM
3Opticaldrivebay1Yourservercomeswithanopticaldriveinstalledinthe5.25-inchopticaldrivebay1.4Opticaldriveeject/closebuttonPressthisbuttontoejectorcloset
FrontpanelThistopicprovidesinformationtohelpyoulocatethecontrol,connectors,andLEDsonthefrontpaneloftheserver.Thefollowingillustrationshowsthecontrol,c
ContentsSafetyinformation...iiiProductsthatarenotassessed...xChapter1.Generalinformation...1Introduction...1Serverdocumen
PowerstatusLEDColorDescriptionOnGreenTheserverison.OffNoneTheserverisoff.BlinkingGreenTheserverisinACPIS1mode,whichalsoisknownasPowerOnSuspend(POS)mod
Potentialsystemerror(systemerrorLED:amber)SolutionApowercordhasbeendisconnectedoraredundantpowersupplyhasbeenremoved.1.Ensurethatthepowersuppliesarein
ThefollowingillustrationshowsthelocationoftheIDMandthediagnosticLEDsontheIDMpanelinthefrontoftheserver.Note:Dependingonthemodel,yourservermightlooksli
LEDStatusDescriptionActionSolidoffThesystemfansareoperatingcorrectly.3SystemfanerrorLEDSolidon(amber)Oneormoresystemfansarerunningatlowspeedorhavebeen
Thefollowingillustrationshowstherearviewoftheserverwithascrew-secured,non-hot-swappowersupplyassembly.Note:Dependingonthemodel,yourservermightlookslig
Yourservermodelmighthaveoneortwohot-swapredundantpowersupplies.Eachhot-swapredundantpowersupplyhasonepowercordconnector1ontherearoftheserver.Foreachho
45Ethernetconnectors(RJ-45)UsedtoattachanEthernetcableforaLAN.EachEthernetconnectorhastwostatusLEDstohelpyouidentifytheEthernetconnectivity,activity,a
ExpansioncardinstallationguidelinesBeforeinstallinganysupportedexpansioncardintoaPCIorPCIExpresscardslot,ensurethatyouobservethefollowingguidelines:•O
PadlockYourservercomeswithapadlockloop.Whenapadlockisinstalled,theservercovercannotberemoved.Figure9.Padlock26ThinkServerTD340UserGuideandHardwareMain
IntegratedcablelockAnintegratedcablelock,sometimesreferredtoastheKensingtonlock,canbeusedtosecureyourservertoanon-permanentfixture.Thecablelockattaches
InstallingtheThinkServerRAIDCacheCadeSoftwareKey...111InstallingorremovingtheThinkServerRAID500UpgradeKeyforAdvancedRAID...112Installingorr
FrontdoorlockYoucanremovethekeyattachedontherearoftheserveranduseittoopenorlockthefrontdooroftheserver.Thefrontdoorprotectsthehard-disk-drivecagesandp
•TheEMIintegrityandcoolingoftheserverareprotectedbyhavingalldrivebayscoveredoroccupied.Thenumberoftheinstalledharddiskdrivesinyourservervariesbymodel.
12Harddiskdrivebay325CPU2DIMMs(varybymodel)13Harddiskdrivebay2Notes:•Thelow-profilePCIcardbracket20andmainPCIcardbracket21areavailableinservermodelstha
8Harddiskdrivebay1525Frontsystemfan29Harddiskdrivebay1426Systemboard10Harddiskdrivebay1327Systemboardbattery11Harddiskdrivebay1228Low-profilePCIcardbra
1Heatsinkandfanassembly211Harddiskdrivebay02CPU1DIMMs(varybymodel)12Frontsystemfan13Heatsinkandfanassembly113Frontsystemfan24IntelligentDiagnosticsMod
DescriptionSelf-serviceCRUOptional-serviceCRUOpticaldriveYesNoPeripheralComponentInterconnect(PCI)card(availableinsomemodels)YesNoPowerdistributionboa
Figure15.3.5-inchhot-swapharddiskdrivestatusLEDs34ThinkServerTD340UserGuideandHardwareMaintenanceManual
Figure16.2.5-inchhot-swapharddiskdrivestatusLEDs1HarddiskdriveactivityLED2HarddiskdriveRAIDstatusLEDDescriptionOffOffTheharddiskdrivehasfailedorisnotp
SomeservermodelscomewitharequiredRAIDcardtoprovideadvancedSATA/SAShardwareRAIDfunctions.IfyourserverdoesnotcomewithaRAIDcard,youcanpurchaseonefromLeno
4ExternalconnectorUsedtoattachthecablethatconnectsaRAIDcardtothesystemboardharddiskdriveLEDconnector.See“Connectingthecables”onpage43.ThinkServerRAID7
SafetyinformationNote:Beforeusingtheproduct,besuretoreadandunderstandthemultilingualsafetyinstructionsonthedocumentationDVDthatcomeswiththeproduct.Ant
ThinkServerRAID710Adapter(alsoknownas9270CV-8iRAIDadapter)ThefollowingillustrationshowstheconnectorsontheThinkServerRAID710Adapter.Figure19.ThinkServe
Thefollowingillustrationshowstheconnectorsontheexpandercard.Eachconnectorontheexpandercardisusedtoconnectamini-SAStomini-SASsignalcable.Fordetailedinf
Thefollowingillustrationshowsthelocationsofthehot-swaphard-disk-drivebackplanes.Youneedtoopentheservercoverandremovethefrontsystemfanstoaccessthebackp
Thefollowingillustrationsshowtheconnectorsona3.5-inchhot-swaphard-disk-drivebackplane.Figure22.Frontviewofthe3.5-inchhot-swaphard-disk-drivebackplane1
2.5-inchhot-swaphard-disk-drivebackplaneThistopicprovidesinformationtohelpyoulocatetheconnectorsonthe2.5-inchhot-swaphard-disk-drivebackplane.Thefollo
2Mini-SASsignalcableconnector1Usedtoconnectthemini-SASconnectorononeendofthemini-SASsignalcable.3Mini-SASsignalcableconnector0Usedtoconnectthemini-SAS
Notes:•ThenumberonthelabelforeachofthefourSATAsignalcablesindicatesthesequencetofollowwhenyouareconnectingthecablestothecorrespondingSATAconnectors(0-
2.Ifyourserverhasmorethanfourharddiskdrivesinstalled,usetheothermini-SAStomini-SASsignalcable.Connectthemini-SASconnector1ononeendofthecabletotheports
2.Useanothermini-SAStomini-SASsignalcableandconnectthemini-SASconnectorononeendofthecabletotheport1ontheThinkServerRAID500Adapter.Then,connectthemini-
Usethefollowinginstructionstoconnectcablesfromtheexpandercardtothe2.5-inchhot-swaphard-disk-drivebackplanes:1.Forharddiskdrive0toharddiskdrive3,useami
PrzedskorzystaniemzproduktunależyzapoznaćsięzwielojęzycznymiinstrukcjamibezpieczeństwaznajdującymisięnapłycieDVDzdokumentacjądostarczonąwrazzproduktem
ThefollowingtableprovidesinformationabouttherecommendedpowerconnectorandsystemboardSATAconnectorforthenon-hot-swapharddiskdriveinstalledineachdrivebay
9Systemfan2connector29InternalUSBconnector5-610Microprocessor1fanconnector30InternalUSBconnector7-811Microprocessor1powerconnector31Systemboardbattery
7PowerManagementBus(PMBus)connectorTheThinkServerManagementModulecanreadthepowersupplystatusregisteredthroughPMBus.Youdonotneedtoconnectanydevicetothe
24InternalUSBTypeAconnectorUsedtoconnectadevicethatusesaUSBTypeAconnector.Forexample,insomesituations,youmightwanttoconnectaUSBkeydirectlytothesystemb
36ThinkServerManagementModuleWiththeintegratedThinkServerManagementModule(hereinafterreferredtoastheTMM),nomatterwhatconditiontheserveroperatingsystem
Thefollowingillustrationshowsthestatusofthejumpersandswitchesonthesystemboardofyourserver.Youcanconfigure,recover,enable,ordisablesomespecificfeaturesof
2ClearCMOSjumperUsedtoclearCMOSandrecoveryourservertothefactorydefaultsettings.Note:AfterclearingCMOS,yourBIOSrecoverstothefactorydefaultsettings.Tocl
3SwitchesTherearefourswitchesonthesystemboardofyourserver.Figure32.SwitchesTable3.Switches1BIOSrecoveryswitch3ManagementEngine(ME)inforceupdateswitch2
2.Iftheserverisinstalledinarackcabinet,removetheserverfromtherackcabinetandplaceitonaflat,clean,andstatic-protectivesurface.SeetheRackInstallationInstr
turnedon.ManyerrorsarefirstindicatedbyaliterrorLEDonthediagnosticpaneloftheserver.IfanLEDislit,oneormoreLEDselsewhereintheservermightalsobelittodirecty
Statement1DANGERElectricalcurrentfrompower,telephone,andcommunicationcablesishazardous.Toavoidashockhazard:•Donotconnectordisconnectanycablesorperform
6ThinkServerManagementModulestatusLEDThisLEDindicatestheThinkServerManagementModule(TMM)statusofyourserver.ThinkServerManagementModulestatusLEDColorDe
Chapter4.TurningonandturningofftheserverThischapterprovidesinformationaboutturningonandturningofftheserver.TurningontheserverTheservercanbeturnedonino
•Theservermightbeturnedoffasanautomaticresponsetoacriticalsystemfailure.Notes:1.Whenyouturnofftheserverandleaveitconnectedtoanacpowersource,theservera
Chapter5.ConfiguringtheserverThischapterprovidesthefollowinginformationtohelpyouconfiguretheserver:•“UsingtheSetupUtilityprogram”onpage61•“UsingtheThink
–SelectSATA/SASConfigurationandfollowtheinstructionsonthescreentoviewinformationabouttheinstalledSATAorSASdevices,suchasaharddiskdriveoranopticaldrive.
Notes:•Enabledmeansthatthefunctionisconfigured.•Disabledmeansthatthefunctionisnotconfigured.TheAdvancedmenucontainsthefollowingsubmenus.Formoreinformati
•BMCStatus:ViewtheBMCstatus.•EraseSEL:Erasesystemeventlog(SEL).•SystemInformation:Viewbasicinformationaboutyourserver.•BMCNetworkConfiguration:SetBMCco
3.UsetheTabkeytoswitchbetweendataelementsandtypethenumbersfromthekeyboardtosetthesystemdateandtime.4.PressF10tosavesettingsandexittheSetupUtilityprogr
2.OntheSecuritymenu,selectAdministratorPasswordtosetanadministratorpasswordorselectUserPasswordtosetauserpassword.3.See“Passwordconsiderations”onpage6
4.PressF10tosavesettingsandexittheSetupUtilityprogram.TheserverwillrestarttoenabletheTPMfunction.ExitingtheSetupUtilityprogramAfteryoufinishviewingorch
Statement3CAUTION:Whenlaserproducts(suchasCD-ROMs,DVDdrives,fiberopticdevices,ortransmitters)areinstalled,notethefollowing:•Donotremovethecovers.Removi
DefaultsontheSave&ExitmenuintheSetupUtilityprogramtorestoretheuserdefaultvaluesafterupdatingtheBIOS.Inthiscase,youcankeepyourpreviousBIOSsettingsa
UsingtheThinkServerEasyStartupprogramThistopicprovidesinstructionsonhowtousetheThinkServerEasyStartupprogramtosetupandconfigureyourserver.TheThinkServe
1.InserttheThinkServerEasyStartupDVDintoanopticaldrive,settheopticaldriveasthefirststartupdevice,andstartyourserverfromtheDVDintheopticaldrive.See“Sele
ThismenuprovidesinstructionsonhowtoconfigureRAIDorviewthecurrentRAIDconfigurationandmakechangesifneeded.•InstalloperatingsystemThismenudisplaysaseriesof
ConfiguringRAIDThistopicprovidesinformationaboutRAIDandtheutilityprogramsthatareavailableforyoutoconfigureRAID.Thistopiccontainsthefollowingitems:•“Abou
•RAID5:block-levelstripingwithdistributedparityRAID5usesdiskstripingandparitydataacrossalldrives(distributedparity)toprovidehighdatathroughput,especia
inserttheThinkServerEasyStartupDVDintotheopticaldrive.TheinstallationpackagesfortheprogramsarelocatedintheUtilitiesandOthersfolderintherootdirectoryof
WhenworkingwiththeLSISoftwareRAIDConfigurationUtilityprogram,youmustusethekeyboard.Thekeysusedtoperformvarioustasksaredisplayedonthebottomofeachscreen.
Table4.LSISoftwareRAIDConfigurationUtilityprogrammenuitems(continued)MenuitemSubmenuitemCommentsAdapterSetadapter-relatedparameters,suchasrebuildrate,c
InitializingavirtualdriveThistopicprovidesinstructionsonhowtoinitializeavirtualdriveusingtheLSISoftwareRAIDConfigurationUtilityprogramaftercompletingth
Statement6CAUTION:Ifyouinstallastrain-reliefbracketoptionovertheendofthepowercordthatisconnectedtothedevice,youmustconnecttheotherendofthepowercordtoa
detailedinformationaboutdiskrebuild,referto“IntroductiontoRAID”intheMegaRAIDSASSoftwareUserGuideonthedocumentationDVDthatcomeswithyourserver.Torebuild
Note:Usingaconsistencycheckrateof0or100percentisnotrecommended.Thedefaultvalueis30percent.1.StarttheLSISoftwareRAIDConfigurationUtilityprogram.See“Star
ForinstructionsonhowtoconfigureandmanagetheadvancedSATA/SAShardwareRAID,refertotheMegaRAIDSASSoftwareUserGuideonthedocumentationDVDthatcomeswithyourser
TodownloadtheLenovoThinkServerEasyManageprogram,gotohttp://www.lenovo.com/driversandfollowtheinstructionsontheWebpage.Fordetailedinformationaboutusing
82ThinkServerTD340UserGuideandHardwareMaintenanceManual
Chapter6.Installing,removing,orreplacinghardwareThischapterprovidesinstructionsonhowtoinstall,remove,orreplacehardwareforyourserver.Thischaptercontain
•Backupallimportantdatabeforeyoumakechangestodrives.•Haveasmallflat-bladescrewdriveravailable.•Youdonothavetoturnofftheservertoinstallorreplaceahot-swa
Note:TheuseofagroundingsystemtoguardagainstESDdamageisdesirablebutnotnecessary.–AttachtheESDgroundcliptoanyframeground,groundbraid,orgreen-wireground.
Thistopicprovidesinstructionsonhowtoremovetheservercover.Beforeyoubegin,printalltherelatedinstructionsorensurethatyoucanviewthePDFversiononanothercomp
6.Pivottheservercoveroutwardtocompletelyremoveit.Figure35.RemovingtheservercoverAttention:Forpropercoolingandairflow,installtheservercoverbeforeturning